Wattplate

Recessed Lighting Calculator

How many lights, how far apart, and how far from the walls.

By Ali (not a licensed electrician) Updated

Recessed lighting inputs

Units

Floor to ceiling.

Halo's 4 in and 6 in canless lights switch between 600, 900 and 1,200 lm.

fc = footcandles: lumens per sq ft.

The spacing criterion (SC) is on the light's spec sheet; Halo's canless lights list 1.15 to 1.23.

From the box. Blank: lumens ÷ 80 lumens per watt.

Rated output

In range

Recessed lights

4lights

A 2 × 2 grid of 900 lm lights: 3 for the light level, 4 for the spacing; the larger count wins.

Apart7.5 × 6 ft
From the walls3.8 × 3 ft
Light level20 fc
LED power45 W
  • Apart: 7 ft 6 in by 6 ft 0 in; no more than 9.2 ft (1.15 × 8 ft)
  • From the walls: 3 ft 9 in from the 12 ft walls, 3 ft 0 in from the 15 ft walls
  • Light level: 3,600 lm; target 15 fc (2,700 lm), typical 10 to 20 fc
  • LED power: 0.4 A at 120 V; 11.25 W a light
  • Ceiling ÷ 2 rule: 12 lights, no more than 4 ft apart. Why the counts differ
  • Where insulation touches the housing or comes within 3 in of it, use IC-rated lights: a non-IC light needs insulation kept 3 in away all round, because insulation against it is a fire hazard (PNNL, DOE). Halo rates its IC lights for air-permeable insulation, not spray foam.
  • That is 0.4 A at 120 V. Lights on for 3 hours or more are a continuous load, so a 15 A circuit should carry no more than 12 A of them (the 80% figure).
  • Turn the power off at the breaker before fitting a light; if you are not qualified, have an electrician do it (Halo's instructions).
  • Rule-of-thumb estimate from lumens per square foot and the maker's spacing rule. A lighting designer sizes real layouts from your light's photometric data.

Working

  1. Area: 15 × 12 ft = 180 sq ft
  2. Light: 180 sq ft × 15 fc = 2,700 lm
  3. By lumens: 2,700 ÷ 900 lm = 3 lights
  4. Spacing limit: 1.15 × 8 ft = 9.2 ft
  5. By spacing: 15 ÷ 9.2 → 2 rows, 12 ÷ 9.2 → 2 columns = 4 lights
  6. Larger count: 4 lights (2 × 2)
  7. Delivered: 4 × 900 lm = 3,600 lm = 20 fc
  8. Power: 4 × 11.25 W = 45 W
  9. Amps: 45 W ÷ 120 V = 0.4 A

Model LF-01

Targets from Penn State, LEDVANCE and Alcon; spacing from Eaton and Halo. Lamp: green inside the room's typical range, amber above it.

Quick answer

A 15 × 12 ft living room with a ceiling of 8 ft needs 4 recessed lights of 900 lm each in a 2 × 2 grid, 7.5 ft apart one way and 6 ft the other, half that from the walls: 45 W in all.

Rule of thumbTypical: a 15 × 12 ft living room needs 2,700 lm (15 fc), 3 lights of 900 lm, but a 9.2 ft spacing limit (1.15 × the 8 ft ceiling) makes it 2 × 2 = 4.

NoteRule-of-thumb estimate from lumens per square foot and the maker's spacing rule. Insulation clearance: NEC 410.116(B), IRC E4004.9; your light's label and local code decide. This is an estimate from physics and maker data, not engineering or code advice. Hire a licensed electrician for the work.

Recessed lights by room size

Counted by this calculator: lights of 900 lm under an 8 ft ceiling, maker spacing (SC 1.15); the last column uses ceiling ÷ 2 at 15 fc.
Room, ftArea, sq ftLiving room (15 fc)Kitchen (35 fc)Ceiling ÷ 2 rule
10 × 10100449
12 × 10120469
12 × 12144469
15 × 121804912
16 × 142244916
20 × 1632061620
20 × 2040091625

Lumens per square foot by room

Typical ambient levels from Penn State, with LEDVANCE or Alcon agreeing; task areas such as counters and a vanity need more.
RoomTypical (fc = lm per sq ft)LuxPreset
Living room10–20108–21515
Bedroom10–20108–21515
Kitchen30–40323–43135
Dining room30–40323–43135
Bathroom20–50215–53835
Hallway5–2054–21510
Garage3032330

How many recessed lights do I need?

A 15 × 12 ft living room with an 8 ft ceiling needs 4 recessed lights of 900 lm: 3 cover its 2,700 lm target, and the maker’s 9.2 ft spacing limit needs a 2 × 2 grid, so the larger count wins.

The light count is the floor area times a target in footcandles, divided by the lumens on one light’s box. A footcandle (fc) is one lumen per square foot; lux is one lumen per square metre. The spacing count keeps every gap under the limit. A larger light count grows the grid a row or column at a time. The watts and amps feed the electricity cost calculator and the breaker size calculator.

Recessed lighting spacing: the maker’s limit and the ceiling ÷ 2 rule

Recessed lights can sit up to the spacing criterion times the ceiling height apart: Halo lists 1.15 for its 4 in and 6 in canless lights, which is 9.2 ft under an 8 ft ceiling. The spacing criterion (SC) is on each light’s spec sheet: Halo’s run 1.15 to 1.23, and Eaton puts most lights at 0.5 to 1.5.

Retail guides such as PacLights and Montreal Lighting halve the ceiling height, 4 ft under an 8 ft ceiling, for a more even wash: 12 lights at 60 fc in the same room. ERCO measures from the working plane, so lighting a counter evenly needs lights closer.

Recessed lighting layout: distance from the wall

Put the outer lights half a spacing from the wall: lights 7.5 ft apart sit 3 ft 9 in from it (ERCO, Montreal Lighting). In the example the lights run 7.5 ft apart along the 15 ft length and 6 ft across the 12 ft width: 3 ft 9 in from the short walls, 3 ft from the long ones.

Lumens, not watts: what 600, 900 and 1,200 lm mean

A 900 lm LED downlight gives more light than a 60 W bulb, which ENERGY STAR rates at 800 lm, and Halo’s 4 in canless light draws 11.5 W at 900 lm. Lumens measure light; watts, the power used. ENERGY STAR puts a 75 W bulb at 1,100 lm and a 100 W bulb at 1,600 lm.

To convert watts to lumens for an LED, read the box or use 80 lm per watt. Halo’s 4 in lights switch between 600 and 900 lm and its 6 in lights between 900 and 1,200 lm, and they dim to 5%.

Watts, amps and the lighting circuit

Four 900 lm recessed LEDs use about 45 W, 0.4 A at 120 V, at 80 lm per watt. The watts to amps calculator does the same sum for any load.

Lights on for 3 hours or more are a continuous load, so a 15 A circuit should carry no more than 12 A of them, the 80% figure (Eaton, IAEI). At 11.25 W a light, the 12 A limit alone allows about 128 lights on one 15 A circuit; boxes, wire and the cable run set the real number, so ask an electrician. Turn the power off at the breaker before fitting a light; if you are not qualified, have an electrician do it (Halo’s instructions).

IC rated, airtight and wet listed: which recessed light to buy

Buy IC-rated lights where insulation will touch the housing or sit within 3 in of it: a non-IC light needs a 3 in gap all round, because insulation against it is a fire hazard (PNNL, DOE). IC means insulation contact. Halo rates its IC lights for air-permeable insulation, not spray foam. NEC 410.116(B) and the IRC set the clearance.

An airtight light stops room air leaking into the attic, which energy codes want in an insulated ceiling (PNNL); Halo certifies its canless lights to ASTM E283. Over a shower or tub (a wet location) use a light listed for wet locations; Halo lists its RL lights for them.

Kitchens, bathrooms and task light

Counters, the sink and the stove need 50 to 100 fc of task light (Penn State), more than a ceiling grid gives, so add under-cabinet lights; a vanity light does the same job at the mirror. The kitchen preset is the general 30 to 40 fc; the bathroom’s sits mid-way in the 20 to 50 fc of Penn State and LEDVANCE.

Worked example

  1. Inputs: a 15 × 12 ft living room (15 fc), 8 ft ceiling, 900 lm lights, maker spacing (SC 1.15).
  2. Area: 15 × 12 ft = 180 sq ft
  3. Light: 180 sq ft × 15 fc = 2,700 lm
  4. By lumens: 2,700 ÷ 900 lm = 3 lights
  5. Spacing limit: 1.15 × 8 ft = 9.2 ft
  6. By spacing: 15 ÷ 9.2 → 2 rows, 12 ÷ 9.2 → 2 columns = 4 lights
  7. Larger count: 4 lights (2 × 2)
  8. Delivered: 4 × 900 lm = 3,600 lm = 20 fc
  9. Power: 4 × 11.25 W = 45 W
  10. Amps: 45 W ÷ 120 V = 0.4 A

Questions people ask

How many recessed lights do I need for a 12 x 15 room?

4 lights of 900 lm for a living room with an 8 ft ceiling: 180 sq ft × 15 fc = 2,700 lm is 3 lights, and the maker's 9.2 ft spacing limit needs a 2 × 2 grid. A kitchen at 35 fc needs 9, and the ceiling ÷ 2 rule would put 12 in the living room.

How far apart should recessed lights be?

No more than the spacing criterion times the ceiling height: Halo lists 1.15 for its canless lights, so 9.2 ft under an 8 ft ceiling. The retail rule of ceiling height ÷ 2 (4 ft at 8 ft) gives a more even wash with more lights. Eaton warns that lights too far apart look like spotlights and lights too close can glare.

How far from the wall should recessed lights be?

Half the spacing between them: lights 7.5 ft apart sit 3 ft 9 in from the wall (ERCO, Montreal Lighting). Much closer than that and the wall gets uneven patches of light, unless you mean to graze it.

How many lumens do I need for a room?

Area × footcandles: living rooms and bedrooms take 10 to 20 lumens per sq ft, kitchens and dining rooms 30 to 40, bathrooms 20 to 50 and hallways 5 to 20 (Penn State, with LEDVANCE or Alcon agreeing). A 180 sq ft living room at 15 needs about 2,700 lm.

Do I need IC-rated recessed lights?

Yes where insulation will touch the housing or sit within 3 in of it: a non-IC light needs a 3 in gap all round, because insulation against it is a fire hazard (PNNL, DOE). Halo rates its IC lights for air-permeable insulation, not for direct contact with spray foam.

How many watts do recessed LED lights use?

About 11 W for a 900 lm light: Halo's 4 in canless light draws 11.5 W at 900 lm, and 4 lights at 80 lm per watt use 45 W, 0.4 A at 120 V. ENERGY STAR rates a 60 W bulb at 800 lm, so each 900 lm light gives more light than one.

Sources

Data last verified: Page updated

Built and checked by Ali, who is not a licensed electrician.

Before you wire anything

These calculators give estimates worked out from physics and published maker data. They are not engineering, design or code advice, and they do not replace an inspection.

Electrical codes differ by edition and by town. Your local inspector, the authority having jurisdiction (AHJ), has the final say on wire size, conduit, boxes and breakers.

Mains wiring can kill and can start fires. Unless you are trained for it, hire a licensed electrician, and get a permit where your town requires one.