Breaker Panel Label Template

Type in your breakers, then print one sheet for the panel door.

By Ali (not a licensed electrician) Updated

Rule of thumbLabel each breaker by its use and a fixed place: 'Kitchen counter outlets, east wall' (NEC 408.4(A)).

Caution

Label from testing, never from guessing. The panel cover stays on.

30 spaces, 18 circuits

Panel scheduleMain panelMain 200 A30 spaces, 18 circuitsNo.What it feedsAmpsMark1-3Range502P5-7Dryer302P9-11Water heater302P13-15Air conditioner, outdoor unit302P17Laundry outlets2019Garage outlets20GFCI21AHall and stair lights1521BAttic fan1523SPARE25EMPTY27EMPTY29EMPTYNo.What it feedsAmpsMark2Kitchen counter outlets, east wall20GFCI4Kitchen counter outlets, island20GFCI6Dishwasher208Refrigerator2010Microwave2012Bathroom outlets, upstairs20GFCI14Primary bedroom outlets, lights15AFCI16Front bedroom outlets and lights15AFCI18Living room outlets and lights15AFCI20Basement lights1522SPARE24EMPTY26EMPTY28EMPTY30EMPTY2P = 2-pole (240 V) · GFCI, AFCI, DUAL (dual-function AFCI/GFCI) = the breaker’s protection21A / 21B = the two halves of a tandem breaker · SPARE = breaker, nothing connected · EMPTY = no breakerLabelled from testing onbyA label is not a reason to skip testing a wire. The panel cover stays on: behind it is a licensed electrician’s job.wattplate.com/breaker-panel-label-template/

The printed sheet lists your breakers in two columns numbered like the panel, odd numbers on the left and even on the right, each line with what the breaker feeds, its amps and its mark. The preview is small on a phone; the printout is full size, and each space below shows its printed line.

A label is not a reason to skip testing a wire.

The door opens; the panel cover (the metal plate around the breaker handles) stays on: removing it is a licensed electrician's job.

Space 1

1-3 · Range · 50 A · 2P

Space 2

2 · Kitchen counter outlets, east wall · 20 A · GFCI

Space 3

Part of 1-3

Space 4

4 · Kitchen counter outlets, island · 20 A · GFCI

Space 5

5-7 · Dryer · 30 A · 2P

Space 6

6 · Dishwasher · 20 A

Space 7

Part of 5-7

Space 8

8 · Refrigerator · 20 A

Space 9

9-11 · Water heater · 30 A · 2P

Space 10

10 · Microwave · 20 A

Space 11

Part of 9-11

Space 12

12 · Bathroom outlets, upstairs · 20 A · GFCI

Space 13

13-15 · Air conditioner, outdoor unit · 30 A · 2P

Space 14

14 · Primary bedroom outlets, lights · 15 A · AFCI

Space 15

Part of 13-15

Space 16

16 · Front bedroom outlets and lights · 15 A · AFCI

Space 17

17 · Laundry outlets · 20 A

Space 18

18 · Living room outlets and lights · 15 A · AFCI

Space 19

19 · Garage outlets · 20 A · GFCI

Space 20

20 · Basement lights · 15 A

Space 21

21A · Hall and stair lights · 15 A 21B · Attic fan · 15 A

21A

21B

Space 22

22 · SPARE

Space 23

23 · SPARE

Space 24

24 · EMPTY

Space 25

25 · EMPTY

Space 26

26 · EMPTY

Space 27

27 · EMPTY

Space 28

28 · EMPTY

Space 29

29 · EMPTY

Space 30

30 · EMPTY

How to label a breaker panel: what each label should say

Give each breaker in the breaker box one clear use and a place that won’t change, such as “Kitchen counter outlets, east wall” or “Furnace, basement”, so anyone can tell it from every other circuit (NEC 408.4(A)). Skip labels that depend on who lives there, like “Bill’s room”: use a compass side, a floor or a permanent room name instead. A breaker with nothing on it is SPARE, and a space with no breaker is EMPTY. The list, which the code calls a directory, usually goes on or inside the panel door. Mark the GFCI and AFCI breakers too. A GFCI breaker has its own TEST button, and how to check a GFCI outlet covers it.

Finding which breaker controls what: a breaker finder or one at a time

There are two ways to match a breaker to what it feeds, both with the panel cover left on: a breaker finder, or switching breakers off one at a time. With a finder, check the outlet works first, plug the transmitter in, scan the breakers with the receiver, then switch the matching breaker off and check the outlet is now dead. One at a time, plug a lamp into the outlet, ask a helper to watch it, and test both halves of each outlet and every light. Write each one down as you confirm it. Labels in older panels are often wrong, so a label is not a reason to skip testing a wire: test it, after checking your tester on an outlet you know is live. The cover stays on because removing it is a licensed electrician’s job.

Panel numbering: odd on the left, even on the right

Most home panels number their spaces 1, 3, 5 down the left and 2, 4, 6 down the right, printed or stamped beside the breakers, so set the tool to the numbers you see. A 2-pole (240 V) breaker takes two stacked spaces on one side, such as 1 and 3, with one handle. The second numbering choice covers panels numbered straight down one side and then the other. A tandem breaker fits two circuits in one space and prints here as 21A and 21B. Tandems fit only where the panel is built for them, and some panels take none. Type the amps marked on each breaker. The breaker size calculator shows what a load draws against a breaker.

Panel schedule template: printing it on Letter or A4

Print at 100% (Actual size) on Letter or A4: the panel schedule fills one sheet, 7.4 by 10 inches, with the two columns laid out like the panel. Only the sheet prints, with no site header, menus or links. Trim it and tape it inside the door, or slide it into the door’s card holder; for a small holder, lower the print scale. This works as an electrical panel schedule template you never retype: change a line and print again. Write the test date in the footer when you label from testing.

Where your panel list is kept

Everything you type stays in this browser on this device: the tool keeps it in the browser’s own storage so it is there next time, and it is never sent anywhere or put in the page link. Clear deletes it, and so does clearing this site’s data. A private window may not keep it, so print or save a PDF if you want a copy. More in the privacy page.

Questions people ask

Spaces or circuits: what is the difference on a breaker panel?

A 30-space panel built for tandem breakers can hold 60 circuits: a space is one full-size breaker position, and a tandem breaker fits two circuits into one space. Square D sells its HOM3060 as 30 spaces and 60 circuits. Many panels take tandems in only some spaces, or none, so check your panel's label or catalog number first.

How are breakers numbered in a panel?

1, 3, 5 down the left and 2, 4, 6 down the right on most home panels, matching the numbers printed or stamped beside the breakers. A 2-pole (240 V) breaker takes two numbers on one side, such as 1 and 3. If your panel's numbers run straight down one side and then the other, pick that order in the tool.

Do I have to label my breaker panel?

Yes: NEC 408.4(A) asks for every circuit to be labelled by a clear, specific use, usually in a directory on or inside the panel door, with spare breakers marked as spare. Your local building department decides how that applies to an existing house.

How do I find which breaker controls an outlet?

Two ways, with the panel cover left on: plug a breaker finder's transmitter into the outlet and scan the breakers with its receiver, or switch breakers off one at a time with a lamp plugged in and a helper watching it. Either way, switch the breaker off and check the outlet is dead before you write its label.

What do the marks on the printed schedule mean?

2P marks a 2-pole (240 V) breaker that spans two numbers; GFCI, AFCI and DUAL (dual-function AFCI/GFCI) name the breaker's protection; 21A and 21B are the two halves of a tandem breaker in space 21; SPARE is a breaker with nothing connected and EMPTY a space with no breaker.

Related calculators

Sources

Checked: Page updated

Built and checked by Ali, who is not a licensed electrician.

This page is general information, not engineering, design or code advice, and it does not replace an inspection. Mains wiring can kill and can start fires: unless you are trained for it, hire a licensed electrician, and get a permit where your town requires one.