Wattplate

Solar Panel Angle Calculator

Tilt angle and direction for your latitude.

Solar panel angle inputs

Latitude of Denver, the largest city. Your own latitude is better: type it.

Declination: east is +, west is −; NOAA's declination calculator gives yours. Roof pitch: the rise per 12.

Rated output

No reading

Year-round tilt

40°

At latitude 39.74° N, tilt your panels 40° from flat, facing true south (azimuth 180°).

Facing (true)South
Azimuth180 °
Oct-Mar tilt55 °
Apr-Sep tilt25 °
Compass reads172.5 °
Roof pitch10/12
  • Twice a year: 55° October-March, 25° April-September (about 4-5% more energy a year).
  • True south reads 172.5° on a compass here (declination 7.5° E).
  • 40° is about a 10/12 roof pitch.
  • Within 10° of this angle you lose about 2% or less a year between 25° and 45° N; an east or west roof makes about 18-27% less than south (NREL PVWatts, EU PVGIS).
  • Panels flush on a roof take the roof's angle; DOE: south-facing roofs of 15-40° work well.

Working

  1. Year-round tilt = latitude = 39.74°, rounded to 40°
  2. October-March tilt = latitude + 15° = 39.74° + 15° = 54.74°, rounded to 55°
  3. April-September tilt = latitude − 15° = 39.74° − 15° = 24.74°, rounded to 25°
  4. Compass reading = azimuth − declination = 180° − 7.5° = 172.5°
  5. Roof pitch = 12 × tan(40°) = 10.07 per 12, about 10/12

Model SE-04

Estimate from NREL PVWatts and EU PVGIS model runs. Shading, roof direction and your installer's design decide the real system.

Quick answer

At a latitude of 39.74°, tilt fixed panels 40° from flat and face true south (azimuth 180°). Changing them twice a year, use 55° from October to March and 25° from April to September.

Rule of thumbTypical: tilt = your latitude (39.74° → 40°), facing true south; twice a year, 55° in winter and 25° in summer.

NoteEstimate from NREL weather models. Shading, roof direction and your installer's design decide the real system. This is an estimate from physics and maker data, not engineering or code advice. Hire a licensed electrician for the work.

Tilt angle by latitude (year-round tilt = the latitude)
LatitudeWinterSummer
25° N40°10°
30° N45°15°
35° N50°20°
40° N55°25°
45° N60°30°
50° N65°35°
Roof pitch in degrees
Roof pitchRoof angle
3/1214°
4/1218.4°
5/1222.6°
6/1226.6°
7/1230.3°
8/1233.7°
9/1236.9°
10/1239.8°
11/1242.5°
12/1245°

Northern hemisphere, panels facing true south. Winter is October-March, summer April-September. In the southern hemisphere use the size of the latitude and face true north.

How the angle is worked out

A fixed solar array collects the most energy over a year when it tilts at about the latitude of the site. A site at 40° north tilts its panels about 40° up from flat, and a site closer to the equator tilts them less. NREL’s PVWatts uses exactly this as its default tilt, and Sandia’s modeling guide says the error is least near the latitude tilt. The calculator rounds your latitude to a whole degree and uses that for the year-round angle.

Pick your state to fill in the latitude of its largest city, or type your own. Your own latitude is better, because a state covers a lot of ground. A map app or the weather page for your town shows it. Use a minus sign for the southern hemisphere.

The two-season angles

The rule most installers quote is to add 15° to the latitude for the dark half of the year and subtract 15° for the bright half. The calculator shows both, with the months each one is for. We checked the rule against NREL PVWatts and the EU JRC PVGIS. Both models agree it works, and both agree on how little it is worth: roughly 4-5% more energy over a year than leaving the array at the latitude angle. If climbing onto a roof twice a year sounds like a poor trade for that, the models agree with you. The two-season angles are useful for adjustable ground mounts and for understanding why a steep array does well in December.

Summer never goes below flat. Close to the equator the subtraction would give a negative angle, so the tool shows 0° and calls it flat.

Which way to face

In the northern hemisphere, point the array at true south, which is an azimuth of 180°. In the southern hemisphere, point it at true north, an azimuth of 0°. The south-facing and north-facing numbers differ because the sun sits in the other half of the sky.

Moving away from south costs energy slowly at first and faster later. The Sandia guide notes that the loss is greatest as the array points away from due south. An east or west facing array makes about 18-27% less in the model runs, which is the figure the calculator prints. A roof that faces somewhat east of south or west of south is often a fine place for panels, and the right choice there is a design decision for your installer.

True south versus your compass

Compasses point to magnetic north, which is not the same place as true north. The difference is the magnetic declination. It is positive where magnetic north lies east of true north and negative where it lies west. To find true south with a compass, subtract the declination from 180°. With a declination of 7.5° east, as in Denver, true south reads 172.5°. In Boston magnetic north lies west of true north, so the declination is negative and true south reads 193.9°.

Enter your declination and the tool does the subtraction for you, including the case where the answer wraps around the compass circle. Declination changes slowly from year to year, so look it up on NOAA’s calculator instead of trusting an old table.

Roof pitch

Roofers state pitch as rise over 12 inches of run. The angle in degrees is the arctangent of the rise divided by 12, so a 12/12 roof is 45°. The calculator turns the year-round tilt into the nearest half step of pitch. If you enter your own pitch, it tells you how many degrees flatter or steeper the roof is than the year-round angle. Flush-mounted panels take the roof’s angle. The Department of Energy describes south-facing roofs between 15° and 40° as working well, which covers most pitched roofs.

What this does not cover

The tool gives angles, not energy. It does not account for shade, snow, the heat of the roof, or the horizon. For how many panels a home needs, use the panel count calculator. For the real design of your system, the installer’s site survey beats any online tool.

Common mistakes

  • Using magnetic south as true south. In parts of the country the two differ by more than 10°.
  • Entering the latitude with the wrong sign. North is positive, south is negative. The tool reads the sign to pick which way to face.
  • Re-tilting for a few percent. The two-season gain is about the size of a normal year-to-year change in weather.
  • Tearing up a roof for the angle. A roof within 10° of the year-round angle loses about 2% or less in the zone where most US homes sit.

Worked example

  1. Inputs: latitude 39.74° N (Colorado), magnetic declination 7.5° E.
  2. Year-round tilt = latitude = 39.74°, rounded to 40°
  3. October-March tilt = latitude + 15° = 39.74° + 15° = 54.74°, rounded to 55°
  4. April-September tilt = latitude − 15° = 39.74° − 15° = 24.74°, rounded to 25°
  5. Compass reading = azimuth − declination = 180° − 7.5° = 172.5°
  6. Roof pitch = 12 × tan(40°) = 10.07 per 12, about 10/12

Questions people ask

What is the best angle for solar panels?

For a fixed array, about your latitude. Denver sits at 39.74° and the tool gives 40°. NREL PVWatts and Sandia both use the latitude as the base case. The cost of being off is small: within 10° of this angle you lose about 2% or less a year between 25° and 45° north, so a roof that is a little flatter or steeper is fine.

Should I change the angle in winter and summer?

You can, but the gain is small. The common rule steps the tilt up 15° for October to March and down 15° for April to September. Runs of NREL PVWatts and the EU JRC PVGIS agree that this adds about 4-5% a year over a fixed angle at the latitude. Most roofs and ground mounts are set once.

Which direction should the panels face?

True south in the northern hemisphere, true north in the southern. An east or west facing array makes about 18-27% less than a south facing one in the PVWatts and PVGIS runs (Denver, facing east, came out 22.6% lower in PVWatts).

Is true south the same as south on my compass?

No. A compass points to magnetic north, and the gap is the magnetic declination, positive when magnetic north lies east of true north. True south reads 180° minus the declination on a compass: 193.9° in Boston and 165.1° in Seattle on 2026-10-10 (NOAA). The declination drifts a little every year, so check NOAA's calculator for today's value.

Does this work in Alaska or the southern hemisphere?

South of the equator the tool uses the size of the latitude and faces the panels true north, with the seasons swapped. Far north, a few degrees flatter than the latitude does as well or better: in PVWatts a Seattle array at 40° made 1.7% more than one at 48°, and PVGIS agrees (1.5%). Above 72° the tool stops and asks you to see a solar designer.

What if my roof pitch decides the angle?

Panels mounted flush on a roof take the roof's angle. A 6/12 roof is 26.6° and a 9/12 roof is 36.9°. The Department of Energy says south-facing roofs of 15-40° work well, so most pitched roofs are close enough that you should not rebuild them for the panels.

Sources

Data last verified: Page updated

Written and checked by Ali, who is not a licensed electrician.

Before you wire anything

These calculators give estimates worked out from physics and published maker data. They are not engineering, design or code advice, and they do not replace an inspection.

Electrical codes differ by edition and by town. Your local inspector, the authority having jurisdiction (AHJ), has the final say on wire size, conduit, boxes and breakers.

Mains wiring can kill and can start fires. Unless you are trained for it, hire a licensed electrician, and get a permit where your town requires one.