Water Heater Size Calculator

First hour rating for a tank, or BTU/h, kW and amps for a tankless heater.

Heater type

How many times each is used in the busiest hour of the day.

Per use: 20 · 2 · 3 · 7 · 25 · 15 gal · other 0 · your FHR none

DOE worksheet figures; edit yours.

First hour rating, from the EnergyGuide label. Fill it to check a heater you already have.

Units

Rated output

No reading

First hour rating needed

87gal

Look for a first hour rating (FHR) of at least 87 gallons on the EnergyGuide label.

Notes
  • DOE counts 20 gallons a shower; Ferguson's pro guide uses 12 and Sobieski 10, so type your own if your showers are short.
  • First hour rating (FHR) is the gallons a full tank delivers in the first hour; it is printed on the EnergyGuide label. For scale: A. O. Smith lists 87 gal FHR for a 40-gal gas power-vent tank and 62 gal for a 50-gal electric tank.
  • Estimate from DOE guidance. Your heater maker and local code decide.
Busiest hour87 gal
In litres330 L

Working

  1. Showers = 3 × 20 gal = 60 gal
  2. Shaves = 1 × 2 gal = 2 gal
  3. Hand dishwashing or food prep = 1 × 3 gal = 3 gal
  4. Dishwasher loads = 1 × 7 gal = 7 gal
  5. Front-loading washer loads = 1 × 15 gal = 15 gal
  6. Busiest hour = 60 + 2 + 3 + 7 + 15 = 87 gal
  7. First hour rating needed = 87 gal rounded up = 87 gal

Model HC-04

Estimate from physics and DOE guidance. Your unit's sizing chart and manual, your code edition and your local inspector decide. The lamp is green or red only when you type your heater's FHR (tank) or a unit's kW (tankless), and red above 36 kW.

Quick answer

In the busiest hour, 3 showers plus a shave, hand dishwashing, a dishwasher and a front-load wash use 87 gallons, so look for a first hour rating of at least 87 gallons (330 litres).

Rule of thumbTypical: DOE counts 20 gallons a shower; 3 showers, a shave, hand dishes, a dishwasher and a front-load wash use 87 gallons in the busiest hour.

NoteEstimate from physics and DOE guidance. Your unit's sizing chart and manual, your code edition and your local inspector decide. This is an estimate from physics and maker data, not engineering or code advice. Hire a licensed plumber or HVAC contractor for the work.

Electric tankless at 240 V, hot water 120 °F: kW over amps, by cold water temperature
GPM40 °F50 °F60 °F70 °F
1.517.67415.46513.25511.046
2.529.412325.710722.09218.477
3.541.1171 *36.015030.812925.7107
558.7245 *51.3214 *44.0184 *36.7153 *

* Larger than the biggest whole-house electric units we found (36 kW). Units this size split their current over several breakers: use the unit's manual for breaker and wire sizes.

DOE worksheet: gallons per use in the busiest hour
UseGallons
Showers20 gal
Shaves2 gal
Hand dishwashing or food prep3 gal
Dishwasher loads7 gal
Top-loading washer loads25 gal
Front-loading washer loads15 gal

DOE Energy Saver worksheet figures. Type your own if yours differ.

Two ways to size a water heater

A storage tank and a tankless heater are sized by different questions. A tank holds hot water in reserve, so the question is how much hot water your home uses in its busiest hour. A tankless heater makes hot water on demand, so the question is how much flow it must heat at once, and by how many degrees. The calculator has a tab for each.

Both tabs print their working with your numbers so you can check it by hand. Metric mode takes litres and °C and still shows the gallons and °F that the maker labels use.

Storage tank: first hour rating

The DOE method adds up the hot water for every use in the busiest hour. The calculator lists showers, shaves, hand dishwashing or food prep, dishwasher loads and top-loading and front-loading washer loads, plus a box for other gallons. Each use has a gallons-per-use figure from the DOE worksheet, and you can edit it.

Those figures sit at the top of the sourced range. DOE counts 20 gallons a shower, while Ferguson uses 12 and Sobieski 10. If your showers are short, type your own number and the answer drops.

The result is a first hour rating (FHR), rounded up to the next gallon. FHR is printed on the EnergyGuide label, and it is how many gallons a full tank delivers in its first hour. Look for a heater whose FHR is at or above the answer. If you already know your heater’s FHR, type it in and the lamp turns green when it covers the demand and red when it does not.

Tankless: flow and temperature rise

Add the flow of every fixture that can run together. A standard shower is 2.5 GPM (EPA WaterSense labels showerheads at 2.0 GPM or less), a faucet is about 1.0, a dishwasher 1.5 and a clothes washer 2.5. Pick a fixture and its preset fills in, or choose Other and type the flow from the label.

The rise is the hot water temperature minus the cold water coming in. DOE suggests assuming 50 °F unless you know otherwise, or holding a thermometer under a cold tap. The heat needed is 500 times the GPM times the rise in °F, in BTU/h. The 500 is the weight of a gallon of water times 60 minutes, and HVAC School and MEP Academy both print it.

For an electric unit the calculator divides by 3,412.14 to get kilowatts and then works out the current from the unrounded kW. Size results round up: BTU/h to the next 1,000, kW to 0.1 and amps to the next whole amp.

Electric units are big

A whole-house electric tankless unit draws a lot. The largest we found are 36 kW at 240 V, which is 150 A. Both EcoSmart and Stiebel Eltron split that current over several breakers and ask for a service of 200 to 300 A, so the calculator does not give a single breaker or wire size. The unit’s manual does.

If your need is above 36 kW, the lamp turns red with a caution. Gas or two electric units may suit better. At 208 V a heater rated at 240 V delivers about 75% of its power, so compare against the 208 V rating on the label.

What it leaves out

This is an estimate. It has no heat pump water heaters, gas input or efficiency, recirculation, solar, gas line or venting, and it does not price running costs. For gas, the answer is a flow and a rise to look up on the maker’s own flow chart.

DOE also advises keeping the hot water setting at 120 °F for most uses, because a higher setting raises the risk of scalding. Your unit’s sizing chart and manual, your code edition and your local inspector decide the final choice.

Worked example

  1. Inputs: 3 showers, 1 shave, 1 hand dishwashing, 1 dishwasher load and 1 front-load wash in the busiest hour.
  2. Showers = 3 × 20 gal = 60 gal
  3. Shaves = 1 × 2 gal = 2 gal
  4. Hand dishwashing or food prep = 1 × 3 gal = 3 gal
  5. Dishwasher loads = 1 × 7 gal = 7 gal
  6. Front-loading washer loads = 1 × 15 gal = 15 gal
  7. Busiest hour = 60 + 2 + 3 + 7 + 15 = 87 gal
  8. First hour rating needed = 87 gal rounded up = 87 gal

Questions people ask

How does the DOE worksheet size a tank?

You add up the gallons for each use in the busiest hour of the day. DOE's worksheet example is 3 showers at 20 gallons, a shave at 2 and hand dishwashing at 3, which add to 65 gallons. Look for a first hour rating at or above that number on the EnergyGuide label.

What is the difference between first hour rating and tank size?

First hour rating (FHR) is how many gallons a full tank delivers in its first hour, so it is usually higher than the tank size. A. O. Smith lists 87 gal FHR for a 40-gal gas power-vent tank and 62 gal for a 50-gal electric tank, which is why the label number matters more than the gallons printed on the tank.

How do I size a tankless water heater?

Add the flow of everything that runs at once, then find the temperature rise from the cold water to the hot setting. DOE's example adds a 0.75 GPM faucet and a 2.5 GPM shower to get 3.25 GPM; at a 70 °F rise that takes 113,750 BTU/h, about 33.4 kW.

Why does winter change the size?

Cold water is colder in winter and in the north. Ferguson's pro guide gives 37 °F in northern Maine, which needs an 83 °F rise to reach 120 °F, against a 48 °F rise in south Florida where the water is 72 °F. A unit that works in Florida can fall short in Maine.

How many amps does an electric tankless heater need?

Amps are kilowatts times 1,000 divided by the volts. A 27 kW unit at 240 V is 112.5 A, and EcoSmart lists 113 A on 3 × 40 A breakers. A 36 kW unit is 150 A, and EcoSmart and Stiebel Eltron both recommend a 300 A service. Use the breaker and wire sizes in the unit manual.

Can an electric tankless heater serve a family of four?

Often not at one time. A shower at 2.5 GPM, a dishwasher at 1.5 and a faucet at 1.0 add to 5.0 GPM, which is more than DOE's figure of about 2 GPM for an electric unit at a 70 °F rise. Gas units manage about 5 GPM at that rise, so gas or two electric units may suit a busy home.

Sources

Data last verified: Page updated

Written and checked by Ali, who is not a licensed electrician.

Before you wire anything

These calculators give estimates worked out from physics and published maker data. They are not engineering, design or code advice, and they do not replace an inspection.

Electrical codes differ by edition and by town. Your local inspector, the authority having jurisdiction (AHJ), has the final say on wire size, conduit, boxes and breakers.

Mains wiring can kill and can start fires. Unless you are trained for it, hire a licensed electrician, and get a permit where your town requires one.