Wattplate

CFM Calculator

Airflow for a room, a bath fan, a range hood or an HVAC system.

What to size
Units

HVI: a complete air change about 8 times an hour.

Rated output

No reading

Airflow needed

96CFM

720 ft³ at 8 air changes an hour needs 96 CFM. Buy a fan of at least 100 CFM.

Notes
  • Rule of thumb: the fan or vent label rating wins. Fan and hood ratings are in CFM.
Volume720 ft³
Airflow in L/s45.3 L/s
Buy a fan of100 CFM

Working

  1. Volume = 10 × 8 × 9 ft = 720 ft³
  2. Airflow = 720 ft³ × 8 ÷ 60 = 96.0 CFM
  3. Fan size = 96.0 CFM rounded up to the next 10 = 100 CFM

Model HC-02

Rule-of-thumb estimate. Fan and hood ratings, your equipment's manual and local code decide; a pro's load and duct design sizes HVAC airflow. Amber only for a range hood above 400 CFM (make-up air, IRC M1503); the other cards have no sourced limit.

Quick answer

A 720 ft³ room at 8 air changes an hour needs 96 CFM (45.3 L/s), so buy a fan of at least 100 CFM.

Rule of thumbTypical: CFM = room volume × air changes per hour ÷ 60: a 10 × 8 × 9 ft bathroom at 8 is 96 CFM, so buy 100.

NoteRule-of-thumb estimate. Fan and hood ratings, your equipment's manual and local code decide; a pro's load and duct design sizes HVAC airflow. This is an estimate from physics and maker data, not engineering or code advice. Hire a licensed HVAC contractor for the work.

Bath fan in CFM by floor area, 8 ft ceiling
Area× 0.13HVI
40 sq ft41.650
60 sq ft62.460
80 sq ft83.280
100 sq ft104fixtures

Volume × 0.13 is the Broan figure. From 100 sq ft the HVI rule adds fixtures instead. The fan is the larger figure, rounded up to the next 10.

Range hood in CFM by gas burner BTU/h
BurnersGas rule
30,000 BTU/h300
45,000 BTU/h450
60,000 BTU/h600
90,000 BTU/h900

BTU/h ÷ 100. The HVI per-foot figure for your range width can be higher; the calculator takes the larger.

Airflow in CFM by tons of cooling, at 350, 400, 450 CFM per ton
Tons350400450
1.5525600675
2700800900
2.58751,0001,125
31,0501,2001,350
41,4001,6001,800
51,7502,0002,250

Your equipment's install manual sets the real airflow.

What CFM means

CFM is cubic feet per minute: how much air a fan, a hood or a duct moves. The calculator has four cards, because the question changes with the room. The room card turns a volume and a number of air changes into airflow. The bath fan card follows the HVI rule and the Broan volume method. The range hood card uses burner heat and the width of the range. The HVAC card links airflow, heat and tons.

Every card prints its working with your numbers, so you can check it by hand. Metric mode shows litres per second, metres, kilowatts and °C beside the fan rating in CFM.

Room airflow from air changes

The room formula is volume times air changes per hour, divided by 60. An air change is one full volume of the room replaced each hour. The chips set the usual starting points: 8 for a bathroom (HVI), 15 for a kitchen under the older HVI rule, and 0.35 for whole-house ventilation (ASHRAE 62.2, quoted by the EPA). You can type any figure from 0.1 to 60.

A fan is sold in steps, so the answer shows the exact airflow and a buy size rounded up to the next 10 CFM. A fan below the exact figure moves less air than the room needs, so the buy size is never lower.

Bath fan size

HVI gives two cases. Under 100 square feet, use 1 CFM per square foot with a floor of 50 CFM. From 100 square feet, add up the fixtures: 50 for a toilet, 50 for a shower, 50 for a bathtub and 100 for a jetted tub. A bathroom of exactly 100 square feet uses the fixtures.

Broan’s help page gives a second method that adds ceiling height: volume in cubic feet times 0.13, rounded up. The card shows both and sizes the fan to the larger. A high ceiling pushes the volume figure above the HVI one.

Range hood CFM

Two rules apply, and the card takes the larger. The first is for gas ranges: add the BTU/h of every burner and divide by 100, which is the rule Proline and World Coppersmith print. The second is HVI’s guidance per linear foot of range, which depends on where the hood sits: 100 against a wall and 150 over an island as the recommended figure, 40 and 50 as the minimum.

Electric ranges use the HVI per-foot figure alone. If you add the kitchen size, the card also shows the older rule of 15 air changes an hour as a cross-check. It never sets the answer, because HVI’s current guidance is per foot of range.

These are guidance figures, not a code requirement. One thing the code does say: a hood that can move more than 400 CFM may need make-up air. The lamp turns amber above that figure as a reminder to check local code and any fuel-burning appliance in the home.

HVAC airflow

For cooling and heating, the sensible heat in air is 1.08 times the CFM times the temperature difference in °F. The 1.08 comes from the density and specific heat of air at 70 °F near sea level, and ACCA points out it is not a true constant: it falls with altitude. The card turns BTU/h into CFM and back, and shows the tons (12,000 BTU/h each).

The third mode multiplies tons by CFM per ton. The usual figure is 400, with 350 for humid climates and 450 for dry ones. Treat the answer as a range: your air handler’s install manual sets the airflow for your equipment, and a pro’s Manual J load calculation and duct design size the system. The calculator does not do either.

What it leaves out

This is a rule-of-thumb estimate for a single room, fan or hood. It does not count duct length or elbows, which cut real airflow, and it has no fan curves, no altitude correction, no downdraft sizing and no make-up air sizing. It also has no engine or carburetor CFM, which is a different question.

Fan and hood ratings on the label, your equipment’s manual and your local code decide the final choice.

Worked example

  1. Inputs: 10 × 8 × 9 ft room at 8 air changes an hour.
  2. Volume = 10 × 8 × 9 ft = 720 ft³
  3. Airflow = 720 ft³ × 8 ÷ 60 = 96.0 CFM
  4. Fan size = 96.0 CFM rounded up to the next 10 = 100 CFM

Questions people ask

How do you calculate CFM for a room?

Multiply length by width by height for the volume in cubic feet, multiply by the air changes per hour you want, and divide by 60. A 10 × 8 ft bathroom with a 9 ft ceiling at 8 air changes an hour needs 720 × 8 ÷ 60 = 96 CFM, so a 100 CFM fan covers it.

What size bathroom fan do I need?

HVI says 1 CFM per square foot for a bathroom under 100 square feet, and at least 50 CFM. From 100 square feet, add 50 CFM for each toilet, shower and bathtub and 100 for a jetted tub. Broan also multiplies the room volume by 0.13 and rounds up to the next 10. The calculator uses the larger of the two.

How many CFM does a range hood need?

For gas, divide the total burner BTU/h by 100 (Proline, World Coppersmith): a 60,000 BTU/h range needs 600 CFM. HVI also gives 100 CFM per foot of range against a wall and 150 over an island. Above 400 CFM, if the home has a fuel-burning appliance that is not direct-vent or power-vented (such as a natural-draft water heater or furnace), the IRC (section M1503) calls for make-up air. Check local code.

How many CFM per ton of air conditioning?

About 400, with 350 for humid climates and 450 for dry ones; those are the three settings on a Trane air handler board. ACCA says the equipment manual sets the real airflow, so use this only as a range.

How do I convert BTU/h to CFM?

CFM = BTU/h ÷ (1.08 × the air temperature difference in °F). 24,000 BTU/h across a 20 °F difference is 1,111 CFM. The 1.08 is for air near sea level and 70 °F and shrinks at altitude.

How many CFM is 100 L/s?

100 L/s is 212 CFM: divide litres per second by 0.4719474. Going the other way, multiply CFM by 0.4719474.

Sources

Data last verified: Page updated

Written and checked by Ali, who is not a licensed electrician.

Before you wire anything

These calculators give estimates worked out from physics and published maker data. They are not engineering, design or code advice, and they do not replace an inspection.

Electrical codes differ by edition and by town. Your local inspector, the authority having jurisdiction (AHJ), has the final say on wire size, conduit, boxes and breakers.

Mains wiring can kill and can start fires. Unless you are trained for it, hire a licensed electrician, and get a permit where your town requires one.